{"id":997585,"date":"2026-11-17T08:00:00","date_gmt":"2026-11-17T07:00:00","guid":{"rendered":"https:\/\/kienzler-klima.de\/?p=997585"},"modified":"2026-11-17T08:07:04","modified_gmt":"2026-11-17T07:07:04","slug":"can-draft-free-office-climate-reduce-sick-days","status":"publish","type":"post","link":"https:\/\/kienzler-klima.de\/en\/can-draft-free-office-climate-reduce-sick-days\/","title":{"rendered":"Can a draught-free indoor climate reduce sick days in the office?"},"content":{"rendered":"<div class=\"vgblk-rw-wrapper limit-wrapper\">\n<p>Yes, a draft-free indoor climate can measurably reduce sick days in the office. Drafts from conventional air conditioning systems stress the mucous membranes, promote the spread of germs, and reduce the ability to concentrate \u2014 all factors directly linked to increased absenteeism. The following sections explain how drafts occur, what damage they cause, and how better air distribution can help in concrete terms.<\/p>\n<h2>How do drafts occur in office buildings?<\/h2>\n<p>Drafts in office buildings occur when conditioned air hits people at too high a flow velocity. Conventional ventilation systems direct air through sheet metal ducts to localized outlets that produce air jets with velocities often exceeding 0.3 m\/s. At these points, a noticeable airflow is created that is perceived as unpleasant or cold.<\/p>\n<p>The problem is compounded by room geometry: ceiling outlets positioned directly above workstations, cold exterior walls near desks, or poorly sealed windows create additional draft effects. Especially in open-plan offices with many heat sources \u2014 monitors, servers, people \u2014 air conditioning systems frequently respond with increased cooling output, which further raises flow velocity. The result: some areas are over-ventilated, others barely at all.<\/p>\n<h2>What complaints does drafts cause in the workplace?<\/h2>\n<p>Drafts in the workplace cause a range of health complaints, from neck tension and dry mucous membranes to cold-like symptoms. The neck, shoulders, and eyes are particularly affected. Persistent airflow dries out the mucous membranes and diminishes their natural protective function against viruses and bacteria.<\/p>\n<p>Commonly reported complaints include:<\/p>\n<ul>\n<li>Headaches and concentration problems due to uneven room temperatures<\/li>\n<li>Dry or irritated eyes, especially during screen work<\/li>\n<li>Tension in the neck and shoulder area due to reflexive muscle contraction<\/li>\n<li>Increased susceptibility to colds, as dried-out mucous membranes are less effective at warding off pathogens<\/li>\n<li>General discomfort and reduced willingness to perform<\/li>\n<\/ul>\n<p>There is also a psychological effect: anyone who feels physically uncomfortable at their workstation concentrates less effectively and is less motivated in the long run. Drafts are therefore not only a medical issue but also an ergonomic one.<\/p>\n<h2>How does draft-free air distribution work with textile systems?<\/h2>\n<p>Draft-free air distribution with textile systems works through the permeability of the fabric used: air does not exit at individual points but evenly across the entire surface of the textile duct. The discharge velocity remains so low that no noticeable draft is created \u2014 the air distributes itself gently and evenly throughout the room.<\/p>\n<p>In contrast to sheet metal ducts with localized outlets, a <a href=\"https:\/\/kienzler-klima.de\/en\/textile-air-ducts-basics\/\">textile air duct<\/a> releases the conditioned air along its entire length. This enables area-wide temperature control without cold or warm zones. The systems can be individually tailored to the room geometry, the type of use, and the desired air volume \u2014 whether as a suspended ceiling system, a wall-mounted variant, or a floor-level duct.<\/p>\n<p>Another advantage: textile systems are significantly lighter than sheet metal ducts and can be quickly cleaned or replaced. In sensitive areas such as offices or <a href=\"https:\/\/kienzler-klima.de\/en\/can-be-used-in-all-areas-and-industries\/\">various industries and applications<\/a>, hygiene also plays an important role \u2014 textile ducts can generally be machine-washed.<\/p>\n<h2>Can better air distribution measurably reduce absenteeism?<\/h2>\n<p>Better air distribution can indeed reduce absenteeism in the office, even if the effect is difficult to measure in isolation. The connection is plausible: those who have no draft-related complaints are less frequently ill, work with greater concentration, and take fewer sick days. Poor indoor air quality is recognized in occupational medicine as an established factor influencing productivity and health.<\/p>\n<p>Studies on indoor air quality consistently show that thermal comfort and even air distribution rank among the most important factors for well-being in the workplace. Drafts directly and persistently disrupt this comfort. Companies that invest in better ventilation technology frequently report fewer complaints from employees \u2014 an indicator that the investment can also pay off economically.<\/p>\n<p>What matters is not only the volume of air introduced, but how it is distributed. Even a powerful air conditioning system with localized outlets can cause draft problems, while a well-designed textile system with low discharge velocities can comfortably condition the same space.<\/p>\n<h2>Which standards regulate air quality in office spaces?<\/h2>\n<p>Air quality in office spaces in Germany is governed by several standards and guidelines. The most important are DIN EN 16798 (Energy performance of buildings: Ventilation for non-residential buildings), ASR A3.6 (Workplace regulation on ventilation), and VDI 6022, which defines hygiene requirements for air handling systems.<\/p>\n<p>ASR A3.6 stipulates that workrooms must be supplied with sufficient fresh air and that drafts must be avoided. Specifically, an air velocity of more than 0.2 m\/s in work areas is considered draft-relevant and should not be persistently exceeded. For the planning of ventilation systems in offices, DIN EN ISO 7730 is also relevant, as it describes thermal comfort in indoor environments and defines limit values for draft risk.<\/p>\n<p>Planners and operators of office buildings are well advised to understand these standards not merely as minimum requirements, but as guidance for ventilation planning that genuinely contributes to the well-being of employees.<\/p>\n<h2>When is it worth switching to a textile ventilation system?<\/h2>\n<p>Switching to a textile ventilation system is particularly worthwhile when existing systems regularly cause draft complaints, when a renovation or new planning is upcoming, or when hygiene requirements are difficult to meet with conventional sheet metal ducts. The switch is also economically attractive: textile systems can be up to 60 percent cheaper than comparable sheet metal solutions in terms of material and installation costs.<\/p>\n<p>Typical situations in which a switch makes sense:<\/p>\n<ul>\n<li>Frequent employee complaints about drafts, cold, or dry air<\/li>\n<li>Uneven temperature distribution in the office despite a running air conditioning system<\/li>\n<li>Renovation or redesign of office spaces with new ventilation planning<\/li>\n<li>New construction, where comfort and efficiency are to be prioritized from the outset<\/li>\n<li>Increased hygiene requirements, such as in laboratories or medical facilities<\/li>\n<\/ul>\n<p>Another factor is sustainability: textile ventilation systems are easier to maintain, clean, and recycle at the end of their service life. The <a href=\"https:\/\/kienzler-klima.de\/en\/countless-variation-options\/\">available product variants<\/a> cover a wide range of requirements.<\/p>\n<h2>How Kienzler Klima ensures a draft-free indoor climate in the office<\/h2>\n<p>At Kienzler Klima, we develop and manufacture textile ventilation systems that solve exactly the problems caused by conventional sheet metal ducts: drafts, uneven temperature distribution, and high maintenance requirements. With over 30 years of experience in air and climate technology and full production at our site in the Allg\u00e4u region, we offer solutions individually tailored to your office space \u2014 with an average production time of just 14 days.<\/p>\n<p>What sets us apart from other providers:<\/p>\n<ul>\n<li><strong>Draft-free air distribution<\/strong> through even discharge along the entire duct length<\/li>\n<li><strong>Individual planning<\/strong> for every floor plan, ceiling height, and type of use<\/li>\n<li><strong>Made in Germany<\/strong> with Cradle-to-Cradle certification for sustainable production<\/li>\n<li><strong>Savings of up to 60%<\/strong> on material and installation costs compared to sheet metal systems<\/li>\n<li><strong>Permanent fire protection<\/strong> chemically anchored in the yarn and non-washable<\/li>\n<\/ul>\n<p>Whether new construction, renovation, or optimization of an existing system: we are happy to advise you on the right options for your office project. <a href=\"https:\/\/kienzler-klima.de\/en\/contact-us\/\">Get in touch now<\/a> and find out how we can permanently improve your indoor climate.<\/p>\n<\/div>\n<p><!-- .vgblk-rw-wrapper --><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Drafts in the office harm health and productivity. Textile ventilation systems can measurably reduce employee absences.<\/p>\n","protected":false},"author":13,"featured_media":999492,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-997585","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-unkategorisiert"],"_links":{"self":[{"href":"https:\/\/kienzler-klima.de\/en\/wp-json\/wp\/v2\/posts\/997585","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kienzler-klima.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kienzler-klima.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kienzler-klima.de\/en\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/kienzler-klima.de\/en\/wp-json\/wp\/v2\/comments?post=997585"}],"version-history":[{"count":1,"href":"https:\/\/kienzler-klima.de\/en\/wp-json\/wp\/v2\/posts\/997585\/revisions"}],"predecessor-version":[{"id":997689,"href":"https:\/\/kienzler-klima.de\/en\/wp-json\/wp\/v2\/posts\/997585\/revisions\/997689"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/kienzler-klima.de\/en\/wp-json\/wp\/v2\/media\/999492"}],"wp:attachment":[{"href":"https:\/\/kienzler-klima.de\/en\/wp-json\/wp\/v2\/media?parent=997585"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kienzler-klima.de\/en\/wp-json\/wp\/v2\/categories?post=997585"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kienzler-klima.de\/en\/wp-json\/wp\/v2\/tags?post=997585"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}